VARIVENT® Mixproof shut-off valves for CIP & gas blocks

VARIVENT® mixproof valves type C and K are used for mixproof separation of incompatible products at pipeline junctions within CIP systems or gas blocks.

Varumärke: GEA
Begär offert
Produktöversikt
Function

When the valve is closed (non-actuated position), there are always two seals between the separated pipelines. If one seal is defective, the resulting leakage will be directed through the leakage outlet into the periphery, without mixing with the product in the second pipeline.

Application Examples

VARIVENT® double-seal valves type C and double-seat valves type K are predominantly used in areas where hygienic is not critical, e.g. CIP systems and gas blocks (brewery)

The Valve Types

Valve type K represents a typical double-seat valve with two independent valve discs in which these two seals are located.

Valve type C, on the other hand, is a double-seal valve in which these two seals are together with the leakage chamber in between them in a valve disc.

In both versions, two seals prevent any mixture between a product line and a line carrying a cleaning media.

Sizes
Double-seal valves, type C valves Double-seat valves, type K
DN 25 – DN 150 DN 25 – DN 150
OD 1″ – OD 6″ OD 1″ – OD 6″
IPS 2″ – IPS 6″
Valve Selection Scheme: Mixproof Shut-off Valves
Application Sealing Feature Type
Product Range Axial Sealing (Switching Leakages) Modular System Double-seat Valve, Type D
Product Range Axial Sealing (Switching Leakages) With Water Hammer Safety Double-seat Valve with Balancer, Type B
Product Range Radial Sealing With Water Hammer Safety Radial Sealing Double-seat Valve, Type R
Product Range Axial Sealing (Switching Leakages) Viscous Products or Products with large Particles Double-seat Long-stroke Valve, Type D_/V
Product Range, piggable Radial Sealing Pigging Pipe
Top
Piggable Double-seat Valve Upside Down, Type L_H
Product Range, piggable Radial Sealing Pigging Pipe Bottom Piggable Double-seat Valve Upright, Type L_S
Gas Blocks &
CIP Systems
Modular System Double-seal Valve, Type C
Gas Blocks &
CIP Systems
Modular System Double-seat Valve, Type K
Cleaning the Leakage Chamber

Double-seal valve type C

In the standard version, two flushing valves are connected to the leakage chamber between the two valve disc seals.

One flushing valve is always used for the leakage outlet, while the second flushing valve is in contact with cleaning media through an olive screw fitting, in order to clean the leakage chamber.

In this case, it is necessary to have a supply valve connected in the periphery to supply the flushing valve with cleaning media at the required time.

Cleaning takes place while the main valve is closed, which means the seal surfaces of the valve disc seals that are in contact are not reached.

Mixproof Valves VARIVENT® C
Mixproof Valves VARIVENT® C

Double-seat valve type K

The double-seat valve type K does have neither an external spraying connection nor a lifting actuator. The leakage chamber is flushed by the fluid that emerges from the leakage chamber as a result of the switching leakage during the main stroke.

For this reason, the valve is not suitable for use in hygienic areas.

The advantages of the valve type K are its slightly increased safety against water hammers that could occur in the lower pipeline, as well as having a wider selection of available housing combinations.

Mixproof Valves VARIVENT® K
Mixproof Valves VARIVENT® K
Technical Data

Type C and K Please refer to the catalog for more information.

Technical Data of the Standard Version

Type C Type K
Material in contact with the product 1.4404 / AISI 316 L
Material not in contact with the product 1.4301 / AISI 304
Seal material in contact with the product EPDM, FKM, HNBR
Ambient temperature 0 to 45 °C
Air supply pressure 6 bar (87 psi)
Product pressure 5 bar (73 psi)
Surface in contact with the product Ra ≤ 0.8 μm DN, OD Ra ≤ 0.8 µm
IPS Ra ≤ 1.2 µm
External housing surface Matte blasted
Control and feedback system Connection 0 (without control top)
Actuator type Pneumatic actuator air / spring
Connection fittings Welding end
Identification Adhesive ID tag
Valve seat version Fixed vertical port Clamped or welded seat ring
Certificates EHEDG, CE A3, CE
Nedladdningsbart material
EN Information leaflet - Sealing set Double-Seal Valve Type C
Product Information
·
Engelska
EN Information leaflet - Sealing set Mixproof Valve Type K
Product Information
·
Engelska
EN Operating instruction - GEA VARIVENT Double seal valve type C
Operating Instruction
·
Engelska
EN Operating Instructions - VARIVENT Mixproof Valve Type K
Operating Instruction
·
Engelska

Har du frågor eller vill du göra en beställning?

"*" indicates required fields

Vill du hitta kontaktuppgifter till en specifik person eller kontor?

Här hittar du alla våra kontaktuppgifter.

Med Colly Flowtech får du alltid

Service

Lokal närvaro

Vi är representerade på åtta orter i Sverige, från Lund i söder till Skellefteå i norr. Vi har dessutom kontor i Danmark.

Colly Flowtech Servicebil

24/7 Service

Vi är tillgängliga dygnet runt, året om, med målet att vara snabbare, bättre och mer engagerade än våra konkurrenter.

Unik produktbredd

Unik produktbredd

På Colly Flowtech erbjuder vi en unik produktbredd inom flödesteknik, med lösningar anpassade för olika branscher och industrier.

Kunder

40+ års erfarenhet

Med över 40 års branscherfarenhet arbetar vi i nära samarbete med våra kunder och med ett starkt engagemang.