T.VIS® E-20 Control Terminal
The T.VIS® E-20 is specially designed to meet the requirements of the fluid processing industry and to provide protection against dust explosions. In addition, all components in this control unit are highly standardized. This ensures the simplest and most time-efficient operation with high reliability and safety.
The technology in the T.VIS® E-20 is based on two separate, magnet-based sensors that are combined into a single sensor module. They are used for limit position detection and provide corresponding feedback signals to the plant’s automation system. The sensor module also provides the optional connection for the pilot solenoid valves to control the valve actuators.
- Proven enclosure technology and standardization of component usage
- Highest protection class as standard
- High resistance to vibration and shock
- Easy Commissioning
- 360° status indication with 2 colors
- Certifications for Global Use
The T.VIS® E-20 comes standard with two position sensors integrated into a compact module. The LED lights, which are also integrated, enable status identification via the illuminated dome built into the control head. The customer’s required wiring to the necessary operating equipment—and thus the intrinsically safe operation of the control head—is achieved through direct wiring to internal spring-loaded terminals, both for the feedback signals and for the valve actuations. To protect the built-in pilot valves, there is a replaceable air filter in the compressed air connection.
Inductive sensor system – The valve's end positions (rest position and fully open position) are detected by two manually adjustable sensors.
The sensors are mounted on the control block and can be adjusted individually over the entire stroke of the valve using two threaded spindles integrated into the sensor module.
LED display
- green: valve in the unoperated position
- yellow: valve at end position
Approved for use in the following applications:
| Type or conformity | ATEX/UKEX/IECEx/CCCEx |
| Application | |
| Gas | (II 2G) Ex ia IIC T4...T5 Gb |
| Ambient temperature | -10 °C ≤ Ta ≤ +42 °C |
| jerk | (II 2D) Ex tb IIIC T85 °C Db |
| Ambient temperature | -10 °C ≤ Ta ≤ +38 °C |
All certifications are based on use in gas and dust atmospheres and meet the requirements for Equipment Category 2 (EPL b).
Technical data of the standard version
| Position detection | Magnetoresistive proximity switches | |
| Housing material | PA 12/L | |
| Air supply | Pressure range | 2 to 8 bar |
| Air supply | Standard | acc. to ISO 8573-1:2010 |
| Air supply | Solid happy | Quality class 6 |
| Air supply | water happy | Quality class 4 |
| Air supply | Oil happy | Quality class 3 |
| Dimensions or air connections | Metric 6/4 mm, inch 6.35/4.31 mm (¼”) | |
| Protection class | IP 69 | |
| Sound pressure level via exhaust air throttle |
Max. 72 dB | |
| Visualization | LED (green, yellow) | |
| Certificates | ATEX, IECEx, UKEx, CCCEx |