T.VIS® A-15 Control Terminal
Development has focused on the requirements and needs of our customers in the fluid handling industry. In addition to reliable control and monitoring of all functions in process valves at breweries, dairies, fruit juice production facilities, and pharmaceutical plants, T.VIS® A-15 offers significant benefits that are directly reflected in a lower total cost of ownership.
- IO link
- Fast, automatic initialization < 1 minute
- Setting tolerances that cannot be manipulated
- Reduced energy consumption
- Reduced operating costs
- Valve Status Indication via LED
- Filters protect solenoid valves
- High-Quality Pneumatic Couplings
- Replaceable compressed air connection
- Throttle valves for supply and exhaust air can be installed
- Logical NOT element
- LEFF® Function
- Semi-automatic adjustment
- Standard protection rating IP66
The T.VIS® A-15 is equipped with a precise position measurement system to detect the valve’s position. The necessary electrical connections for control and feedback are made, depending on requirements, via the M12 connectors accessible from the outside or through direct cable routing and cable glands. The control top can be opened for this purpose.
The T.VIS® A-15 is operated and configured either using the two push buttons on the cover or, when the cover is removed, using the buttons below. The push buttons are electronically protected against accidental or incorrect use when in operating mode.
A replaceable filter in the pressure relief connection protects the solenoid valves.
Position Measurement System – The valve's position is detected using a state-of-the-art position measurement system.
Automatic – After unlocking, simply pressing the two buttons on the hood of the T.VIS® A-15 starts the initialization process, which runs completely automatically. The Control Top does not need to be opened for this, resulting in a particularly fast, simple, and safe commissioning of the control head (on average < 1 minute).
Immediately after installation, you can set the tolerances for the open/closed positions and the signal attenuation in the parameter menu.
Activation of the main stroke, which may be required in VARIVENT® and ECOVENT® valves with an open, unoperated position for valve maintenance, is performed using the service mode, which can be activated with the buttons. At the same time, all feedback signals (warnings to the system controller) are stopped.
To protect maintenance personnel, T.VIS® also does not implement input signals from the control system.
T.VIS® A-15 Please refer to the catalog for more information.
Technical Data of the Standard Version
| Position detection | Path measuring system | |
| Housing material | PA12/L | |
| Ambient temperature
|
-20 to +55 °C | |
| Air supply | Pressure range | 2 to 8 bar |
| Air supply | Standard | acc. to ISO 8573-1:2010 |
| Air supply
|
Solid content | Quality class 6 |
| Air supply | Water content | Quality class 4 |
| Air supply | Oil content | Quality class 3 |
| Dimensions of air connections | Metric 6/4 mm, inch 6.35/4.31 mm (¼”) | |
| Protection class | IP66 (powerful water jet) | |
| Sound pressure level via exhaust air throttle | Max. 72 dB | |
| Visualization | LED (green, yellow, red) | |
| Certificates | optional: UL/CSA, only for indoor use and only with interface type A, B, D, and I | |
| Certificates | optional: UL 121201 - Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Clas III, Divisions 1 and Hazardous (Classified) Locations | |
| CSA C22.2 No. 213-17 | Non-incendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous |